HOSPITAL ELEVATORS

In a Hospital, an Elevator Isn't Transport. It's Part of the Chain of Care.

Stretcher-deep cabins, fast vertical movement, and uninterrupted reliability — engineered so the lift is never the reason a patient waits. BIS & ISO certified, ARD-protected, IS 17900, 25 years and zero incidents.

Overview

A hospital lift is not a passenger lift with a wider door. It carries patients, beds, and the people keeping them alive — which makes stretcher clearance, speed, hygiene and reliability clinical requirements, not features. Span builds to that bar.

The Span Difference

Built around the stretcher, not the passenger.

An extra-deep 2400 mm car takes a hospital bed, a stretcher, and the team moving with it — without anyone turning sideways.

Capacity for the whole entourage.

15, 20 or 26 passengers (1020–1768 kg) — patient, bed, attendants and equipment in a single trip.

Hygiene is a spec, not a finish.

Anti-bacterial surfaces, easy-clean stainless interiors, touchless controls — built for infection control.

Fast when fast is the difference.

Up to 1.5 m/s, because in emergency transport the lift cannot be the slow link.

Specifications

Telescopic auto door (mm)

PersonsLoad (kg)SpeedShaft W (A)Shaft D (B)Car W (C)Car D (D)Entr (E)M/Room W (F)M/Room D (G)
151020up to 1.5180029001000240080037505500
201360up to 1.52200300013002400120042005500
261768up to 1.52350300016002400120042005500

(15 & 20-passenger models also available with manual imperforate doors.)

Civil & structural: Walls min. 150 mm RCC or 225 mm brick masonry · Pit depth min. 1800 mm below bottom floor · Overhead clearance min. 2500 mm from top floor to machine-room slab underside · Machine room per F × G above, with trap door (500 × 800 mm) and exhaust fan.

Safety & Compliance

Six safety systems, standard — not optional: two-way emergency intercom to the control room, Auto Rescue Device for power failures, infrared door curtain + obstruction sensors, overload protection (audio-visual alarm + door hold), fire service mode (priority floor recall on alarm), and a dedicated stretcher-priority operation mode. BIS & ISO certified, IS 17900. 25 years, zero incidents.

Configurations / Options

Doors: telescopic auto (all models) or manual imperforate (15 & 20-passenger). Wide entrances 800–1200 mm. Anti-bacterial stainless cabin. Priority floor recall, emergency power operation.

Applications

Hospitals (multi-specialty & super-specialty) · medical centres & diagnostics · emergency / trauma / ICU transport · operation theatres · nursing homes · rehabilitation centres.

Where the Elevator Is Never Allowed to Be the Weak Link.